Contributing

What is the reason for RSD failure in HPLC?

What is the reason for RSD failure in HPLC?

Column temperature fluctuations (especially evident in ion exchange systems). Column overloading. (Retention times usually decrease as mass of solute injected on column exceeds column capacity.) Sample solvent incompatible with mobile phase.

What is a system suitability failure?

When a system suitability test fails, an investigation into the cause is required. Data generated from the analysis cannot be used. Ideally analytical results should not be generated until the system suitability test results have been shown to pass.

What is system suitability for HPLC?

System suitability is to prove that system is working perfectly before the analysis on HPLC, GC, TOC analyzer or any other system. It is required to done before every sample analysis. In the HPLC technique, a liquid sample is passed over an absorbent material to test its efficacy.

What factors affect HPLC?

For a particular compound, the retention time will vary depending on:

  • the pressure used (because that affects the flow rate of the solvent)
  • the nature of the stationary phase (not only what material it is made of, but also particle size)
  • the exact composition of the solvent.
  • the temperature of the column.

What is the purpose of system suitability?

The System Suitability Testing (SST) is used to verify that an analytical method was suitable for its intended purpose the day the analysis was done. It is an essential parameter to ensure the quality of the method for correct measurements.

What are system suitability parameters?

System suitability test (SST) is a test to determine the suitability and effectiveness of chromatographic system prior to use. These mixtures are used to establish characteristic chromatographic parameters, such as the number of effective theoretical plates, resolution, asymmetry, detection limit and selectivity.

What are the system suitability parameters?

What are the advantages and disadvantages of HPLC?

Disadvantages & Advantages of an HPLC

  • HPLC and Similar Techniques. Like other forms of chromatography, HPLC allows the separation of chemical constituents through the use of a mobile phase and a stationary phase.
  • Speed, Efficiency and Accuracy.
  • Cost and Complexity.
  • Sensitivity and Resolution.

What is Ghost peak in HPLC?

Ghost peaks are contaminant peaks that appear even when no sample is injected. There are many causes for ghost peaks and this note will describe how to troubleshoot these contaminant peaks, when you see them. The primary cause of a ghost peak is a dirty pre-column or column.

What are the regulatory aspects of HPLC analysis?

Regulatory Aspects of HPLC analysis (System Suitability) ©2005 Waters Corporation Introduction What is System Suitability? • A way of checking that an entire chromatography system is working within acceptable limits – For a single day, or tracking and trending over time • Set of Samples to test the system at the point of use

How is system suitability determined in HPLC analysis?

Pharmaceutical scientists use statistical analyses to set realistic System Suitability Testing limits. An optimum system should provide the maximum information out of a minimum number of tests.

What are the consequences of a HPLC failure?

The consequences of the failure are not severe: the cause is documented and the analysis repeated. However, regular failures are of concern and may indicate a more serious root cause. The test measures the operation of an HPLC method in a holistic fashion and the reasons for failure of the test are varied. The most common reasons are related to:

What are the tips and tricks of HPLC troubleshooting?

Tips and Tricks of HPLC System Troubleshooting Agilent Technologies, Inc. LC Tips And Tricks Seminar Series Page 2 Trouble Shooting Steps You Have Recognized There is a Problem! How Do You Fix It? •1stDid System Suitability or Sample Fail? •2ndReview Method for Compliance –Is The Procedure Being Followed Properly?