Why is my furnace running when thermostat is off?

Why is my furnace running when thermostat is off?

The fan limit switch is responsible for turning the blower on and off at the appropriate times. So, when the switch is working correctly, your furnace fan should turn on several minutes after thermostat calls for heat and turn off several minutes after the heat cycle ends.

What causes a furnace to keep running?

When a furnace runs constantly, it probably means that something is dirty or clogged. But if the furnace fan continues to blow, there could be an electrical problem between the thermostat and the furnace or air blower, which requires a professional repair.

Why is my furnace not stopping?

If your furnace won’t shut off, you likely have one of the following problems: Incorrect setting on thermostat. Dirty air filter. Broken blower fan motor.

How long can a furnace run continuously?

If your furnace is operating correctly, it should cycle about 2 to 3 times per hour. How long it operates depends on how cold it is outside. In milder temperatures, it may run for 10 to 15 minutes. The colder it gets, the longer the run cycle will be.

What do you do if your furnace keeps running?

What you can do if your furnace won’t stop running:

  1. Check the thermostat setting.
  2. Inspect the air filter.
  3. Look into weatherizing.
  4. Check your ductwork.
  5. Check the vents.
  6. Check the thermostat.
  7. When you need heating equipment installation, maintenance and repairs, trust P.

How do I know if my heat sequencer is bad?

Another sign of a bad sequencer is when your furnace kicks on and runs normally but it doesn’t heat your house very well. This happens when the first coil heats up but the other coils don’t get a signal from the sequencer to start heating.

What do you do when your heater won’t turn off?

Check Your Thermostat If your furnace wont shut off and you’re worried, don’t panic. The first thing to do is check the thermostat. Check whether your fan is set to On or Auto. If it’s On, try setting it to Auto — this will turn the fan off when the temperature reaches the desired setting.

Why does my furnace keep running after the temp is reached?

As a result, the fan will continue to run. On the other hand, if you notice that your furnace is still running after it reached your desired temperature, it means the furnace is not getting the message that it’s already accomplished its goal. This can also happen when certain parts in your furnace is broken or damaged.

When do you turn off the Furnace Fan?

So, when the switch is working correctly, your furnace fan should turn on several minutes after thermostat calls for heat and turn off several minutes after the heat cycle ends. But if the furnace fan runs continuously, regardless of whether the furnace is heating or not, your furnace fan limit switch is either:

Is it normal for a Furnace Fan to run all the time?

When your thermostat is set to AUTO, your furnace fan should blow only when your furnace is in the middle of a heating cycle. But if your fan runs constantly, regardless of whether your furnace is heating, that’s not normal.

What to do if your furnace wont set the thermostat?

Although faulty ductwork can seriously inhibit your furnace’s ability to reach the temperature you set the thermostat to, it’s a pretty easy fix. Simply use HVAC tape to cover up any leaks and reattach any sections that have become detached. There’s nothing to it.